The role of inferior vena cava diameter in the differential diagnosis of dyspneic patients; best sonographic measurement method?☆
Affiliations
- Haseki Training and Research Hospital, İstanbul, Turkey
Correspondence
- Corresponding author at: Department of Emergency Medicine, Haseki Training and Research Hospital, 34096 Istanbul, Turkey. Tel.: +90 5432222570.

Affiliations
- Haseki Training and Research Hospital, İstanbul, Turkey
Correspondence
- Corresponding author at: Department of Emergency Medicine, Haseki Training and Research Hospital, 34096 Istanbul, Turkey. Tel.: +90 5432222570.

Affiliations
- İzmir Bozyaka Training and Research Hospital, İzmir, Turkey
Affiliations
- İzmir Bozyaka Training and Research Hospital, İzmir, Turkey
Affiliations
- Şanlıurfa Mehmet Akif Ersoy Training and Research Hospital, Şanlıurfa, Turkey
Affiliations
- İzmir Bozyaka Training and Research Hospital, İzmir, Turkey
Affiliations
- Gaziantep Dr. Ersin Arslan State Hospital, Gaziantep, Turkey
Affiliations
- İzmir Bozyaka Training and Research Hospital, İzmir, Turkey
Article Info
To view the full text, please login as a subscribed user or purchase a subscription. Click here to view the full text on ScienceDirect.
Figure
Inferior vena cava measurement methods.
Abstract
Study objective
We aimed to determine the role of inferior vena cava (IVC) diameter in making a differentiation between dyspnea of cardiac (acute heart failure [AHF]) and pulmonary origin. We also attempted to determine the best sonographic method for the measurement of IVC diameter.
Methods
This prospective observational study was conducted at the intensive care unit of the emergency department of a training and research hospital. This study enrolled patients with the main symptom of dyspnea who were categorized into 2 groups, cardiac dyspnea and pulmonary dyspnea groups, based on the final diagnosis. All patients underwent sonographic measurement of minimum and maximum diameters of IVC, and the caval index (CI) was calculated in both M-mode and B-mode. The sensitivity, specificity, and likelihood ratios (LR) of the IVC values for the differentiation of the 2 groups were calculated.
Results
This study included a total of 74 patients with a mean age of 72.8 years. Thirty-two patients had dyspnea of cardiac origin, and 42 patients had dyspnea of pulmonary origin. The IVC diameter measured with B-mode during inspiration (B-mode i) was the most successful method for differentiation of the 2 groups. B-mode i values greater than 9 mm predicted dyspnea of cardiac origin with a sensitivity of 84.4% and a specificity of 92.9% (+LR: 11.8, LR: 0.16).
Conclusion
Sonographic assessment of the IVC diameter may be used as a rapid, readily, nonexpensive, complication-free, and reproducible technique for the differentiation of cardiac and pulmonary causes of dyspnea. B-mode i measurement may be more successful in the differentiation of dyspnea compared with other IVC diameters and calculations.
To access this article, please choose from the options below
Purchase access to this article
Claim Access
If you are a current subscriber with Society Membership or an Account Number, claim your access now.
Subscribe to this title
Purchase a subscription to gain access to this and all other articles in this journal.
Institutional Access
Visit ScienceDirect to see if you have access via your institution.
☆Prior presentations: Preliminary data presented at the 1.İnternational Critical Care and Emergency Medicine Congress, Istanbul, 2013.
Related Articles