The effectiveness of bedside point-of-care ultrasonography in the diagnosis and management of metacarpal fractures
Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Correspondence
- Corresponding author at: Antalya Education and Research Hospital, Department of Emergency Medicine, 07100, Antalya, Turkey. Tel.: +90 507796560.

Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Correspondence
- Corresponding author at: Antalya Education and Research Hospital, Department of Emergency Medicine, 07100, Antalya, Turkey. Tel.: +90 507796560.

Affiliations
- Adana Numune Education and Research Hospital, Department of Emergency Medicine, Adana, Turkey
Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Affiliations
- Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey
Article Info
To view the full text, please login as a subscribed user or purchase a subscription. Click here to view the full text on ScienceDirect.
Fig. 1
Joint space, epiphyseal line, and fracture can be easily seen in the US image of a 10-year-old male patient.
Fig. 2
Posteroanterior and lateral DRs of the same patient shown in Fig. 1 .
Abstract
Objective
We aimed to compare the effectiveness of point-of-care ultrasonography (POCUS) with direct radiography (DR) in the diagnosis and management of the patients with metacarpal fractures (MFs).
Methods
Patients between ages 5 and 55 years admitted to the emergency department with suspected MFs were included to the study. Emergency physicians (EPs) participating in the study were divided into 2 groups (POCUS, DR). Patients were evaluated by one of the EPs from each group. The EP performing the POCUS examination was blinded to the radiograph results.
Results
A total of 66 patients with MFs were included to the study. Fracture was determined in 36 (55%) patients with DR and in 37 (56%) patients with POCUS. When compared with radiography, the sensitivity of fracture detection with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 90% (95% confidence interval, 80%-98%). Sensitivity of detecting localization of the fracture with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 89% (95% confidence interval, 80%-98%). Of the patients with fracture, 69% have angulation and 24% have step-off determined with POCUS. Specificity of POCUS in the decision for treatment choice was 100%, and sensitivity was 99%.
Conclusion
We found that POCUS could be applied easily with success by EPs in diagnosing MFs, determining the type of the fracture and required treatment methods correctly. Point-of-care US can be used to rule out a suspected MF, thereby avoiding the time and expense of radiography.
To access this article, please choose from the options below
Purchase access to this article
Claim Access
If you are a current subscriber with Society Membership or an Account Number, claim your access now.
Subscribe to this title
Purchase a subscription to gain access to this and all other articles in this journal.
Institutional Access
Visit ScienceDirect to see if you have access via your institution.
Related Articles
Searching for related articles..