Corrected carotid flow time and passive leg raise as a measure of volume status

Published:October 22, 2018DOI:https://doi.org/10.1016/j.ajem.2018.10.047

      Abstract

      Background

      The aim of this study was to investigate the value of corrected carotid flow time (FTc) with passive leg raise (PLR) as a non-invasive marker of volume status in end stage renal disease (ESRD) patients.

      Methods

      Prospective observational study of ESRD patients presenting to the Emergency department requiring hemodialysis. The common carotid artery was evaluated in long axis. Flow time measurements pre- and post-dialysis as well as before and after PLR were recorded.

      Results

      54 patients were enrolled, of which, 30 (55%) were male. The mean age was 47.4 years. The mean volume of fluid removed was 3.89 ± 0.91 L. In the pre-dialysis cohort, the mean FTc was 340.16 ms (95% CI, 330.36–349.95). Following PLR, the mean FTc was 341.34 ms (95% CI 331.74–350.94). In the post hemodialysis cohort, the mean FTc was 302.48 ms (95% CI, 293.63–311.32). Following the PLR maneuver, the mean FTc was 340.49 ms (95% CI 331.97–349.02). The mean decrease in corrected carotid flow time was 19.15 ms (95% CI, 22.86–41.17), 32.02 ms (95% CI 4.05–34.25) and 41.17 ms (95% CI, 36.47–54.76) for patients who had <3 L, 3-4 L and >4 L removed, respectively. In patients without CHF, the mean decrease in FTc after hemodialysis was 38.80 ms (95% CI, 30.12–47.49) whereas for CHF patients the mean decrease was 35.60 ms (95% CI, 25.05–46.15).

      Conclusion

      Corrected flow time in conjunction with passive leg raise seem to correlate with volume status in hemodialysis patients.

      Keywords

      To read this article in full you will need to make a payment
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to The American Journal of Emergency Medicine
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Rivers E.
        • Nguyen B.
        • Havstad S.
        • Ressler J.
        • Muzzin A.
        • Knoblich B.
        • et al.
        Early goal-directed therapy in the treatment of severe sepsis and septic shock.
        N Engl J Med. 2001; 345: 1368-1377
        • Pro C.I.
        • Yealy D.M.
        • Kellum J.A.
        • Huang D.T.
        • Barnato A.E.
        • Weissfeld L.A.
        • et al.
        A randomized trial of protocol-based care for early septic shock.
        N Engl J Med. 2014; 370: 1683-1693
        • Eskesen T.G.
        • Wetterslev M.
        • Perner A.
        Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness.
        Intensive Care Med. 2016; 42: 324-332
        • Marik P.E.
        • Cavallazzi R.
        Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense.
        Crit Care Med. 2013; 41: 1774-1781
        • Durairaj L.
        • Schmidt G.A.
        Fluid therapy in resuscitated sepsis: less is more.
        Chest. 2008; 133: 252-263
        • Boyd J.H.
        • Forbes J.
        • Nakada T.A.
        • Walley K.R.
        • Russell J.A.
        Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality.
        Crit Care Med. 2011; 39: 259-265
        • Airapetian N.
        • Maizel J.
        • Alyamani O.
        • Mahjoub Y.
        • Lorne E.
        • Levrard M.
        • et al.
        Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?.
        Crit Care. 2015; 19: 400
        • Barbier C.
        • Loubieres Y.
        • Schmit C.
        • Hayon J.
        • Ricome J.L.
        • Jardin F.
        • et al.
        Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.
        Intensive Care Med. 2004; 30: 1740-1746
        • Dipti A.
        • Soucy Z.
        • Surana A.
        • Chandra S.
        Role of inferior vena cava diameter in assessment of volume status: a meta-analysis.
        Am J Emerg Med. 2012; 30 ([e1411]): 1414-1419
        • Long E.
        • Oakley E.
        • Duke T.
        • Babl F.E.
        • Paediatric Research in Emergency Departments International C
        Does respiratory variation in inferior vena cava diameter predict fluid responsiveness: a systematic review and meta-analysis.
        Shock. 2017; 47: 550-559
        • Monnet X.
        • Rienzo M.
        • Osman D.
        • Anguel N.
        • Richard C.
        • Pinsky M.R.
        • et al.
        Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients.
        Intensive Care Med. 2005; 31: 1195-1201
        • Blehar D.J.
        • Glazier S.
        • Gaspari R.J.
        Correlation of corrected flow time in the carotid artery with changes in intravascular volume status.
        J Crit Care. 2014; 29: 486-488
        • Hossein-Nejad H.
        • Mohammadinejad P.
        • Lessan-Pezeshki M.
        • Davarani S.S.
        • Banaie M.
        Carotid artery corrected flow time measurement via bedside ultrasonography in monitoring volume status.
        J Crit Care. 2015; 30: 1199-1203
        • Mackenzie D.C.
        • Khan N.A.
        • Blehar D.
        • Glazier S.
        • Chang Y.
        • Stowell C.P.
        • et al.
        Carotid flow time changes with volume status in acute blood loss.
        Ann Emerg Med. 2015; 66 ([e271]): 277-282
        • Lafanechere A.
        • Pene F.
        • Goulenok C.
        • Delahaye A.
        • Mallet V.
        • Choukroun G.
        • et al.
        Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients.
        Crit Care. 2006; 10: R132
        • Preau S.
        • Saulnier F.
        • Dewavrin F.
        • Durocher A.
        • Chagnon J.L.
        Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.
        Crit Care Med. 2010; 38: 819-825
        • Monnet X.
        • Rienzo M.
        • Osman D.
        • Anguel N.
        • Richard C.
        • Pinsky M.R.
        • et al.
        Passive leg raising predicts fluid responsiveness in the critically ill.
        Crit Care Med. 2006; 34: 1402-1407
        • Maizel J.
        • Airapetian N.
        • Lorne E.
        • Tribouilloy C.
        • Massy Z.
        • Slama M.
        Diagnosis of central hypovolemia by using passive leg raising.
        Intensive Care Med. 2007; 33: 1133-1138
        • Inrig J.K.
        Intradialytic hypertension: a less-recognized cardiovascular complication of hemodialysis.
        Am J Kidney Dis. 2010; 55: 580-589