Ultrasound measurement of inferior vena cava collapse predicts propofol-induced hypotension
Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Correspondence
- Corresponding author at: 1020 Sansom Street, Suite 239 Thompson Buildling, Philadelphia, PA, 19107. Tel.: +1 215 955 6844; fax: +1 215 923 6225.

Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Correspondence
- Corresponding author at: 1020 Sansom Street, Suite 239 Thompson Buildling, Philadelphia, PA, 19107. Tel.: +1 215 955 6844; fax: +1 215 923 6225.

Affiliations
- Department of Anesthesiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Affiliations
- Department of Family and Community Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Affiliations
- Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
Article Info
To view the full text, please login as a subscribed user or purchase a subscription. Click here to view the full text on ScienceDirect.
Abstract
Study Objectives
Hypotension is a common side effect of propofol, but there are no reliable methods to determine which patients are at risk for significant propofol-induced hypotension (PIH). Ultrasound has been used to estimate volume status by visualization of inferior vena cava (IVC) collapse. This study explores whether IVC assessment by ultrasound can assist in predicting which patients may experience significant hypotension.
Methods
This was a prospective observational study conducted in the operating suite of an urban community hospital. A convenience sample of consenting adults planned to receive propofol for induction of anesthesia during scheduled surgical procedures were enrolled. Bedside ultrasound was used to measure maximum (IVCmax) and minimum (IVCmin) IVC diameters. IVC-CI was calculated as [(IVCmax-IVCmin) / IVCmax x 100%]. The primary outcome was significant hypotension defined as systolic blood pressure (BP) below 90 mmHg and/or administration of a vasopressor to increase BP during surgery.
Results
The study sample comprised 40 patients who met inclusion criteria. Mean age was 55 years, (95%CI, 49-60) with 53% female. 55% of patients had significant hypotension after propofol administration. 76% of patients with IVC-CI≥50% had significant hypotension compared to 39% with IVC-CI<50%, p=0.02. IVC-CI≥50% had a specificity of 77.27% (95%CI, 64.29%-90.26%) and sensitivity of 66.67% (95%CI, 52.06%-81.28%) in predicting PIH. The odds ratio for PIH in patients with IVC-CI≥50% was 6.9 (95%CI, 1.7-27.5).
Conclusion
Patients with IVC-CI≥50% were more likely to develop significant hypotension from propofol. IVC ultrasound may be a useful tool to predict which patients are at increased risk for PIH.
To access this article, please choose from the options below
Purchase access to this article
Claim Access
If you are a current subscriber with Society Membership or an Account Number, claim your access now.
Subscribe to this title
Purchase a subscription to gain access to this and all other articles in this journal.